Vornado PCO500 Specifications

Browse online or download Specifications for Air filters Vornado PCO500. Vornado PCO500 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
READ AND SAVE THESE INSTRUCTIONS
Whole Room Air Purifier Owner’s Guide
LEER Y GUARDAR ESTAS INSTRUCCIONES
Guía para el usuario del Purificador de Aire para todo el ambiente
LISEZ ET CONSERVEZ CES INSTRUCTIONS
Manuel d’utilisation du Purificateur d’Air pour Espace Entier
www.vornado.com
model PCO300 and PCO500
Page view 0
1 2 3 4 5 6 ... 25 26

Summary of Contents

Page 1

READ AND SAVE THESE INSTRUCTIONSWhole Room Air Purifier Owner’s GuideLEER Y GUARDAR ESTAS INSTRUCCIONESGuía para el usuario del Purificador de Aire para

Page 2 - 2 English

10 EnglishUnderstanding CADRWhat is CADR? CADR stands for "Clean Air Delivery Rate," which indicates the volume of filtered air delivered by

Page 3 - Contents

11EnglishSLEEPControl PanelPCO500 picturedAirflow AdjustmentAdvanced CarbonFilter ReplacementHEPA FilterReplacementPower7silverscreen™ReplacementUV Bul

Page 4 - IMPORTANT INSTRUCTIONS

12 English Particle Sensing Mode Odor Sensing ModeParticle Sensing Mode and Odor Sensing Mode monitors the air qual-ity of

Page 5

13EnglishSLEEPHow To Usewhen fewer airborne contaminants are present in the room. Because active people and pets tend to stir up airborne particles an

Page 6 - 6 English

14 Englishdemanding environment, you may need to change the Filters or Trays more frequently. In less polluted environments the Filter and Tray life

Page 7 - Product Information

15EnglishPURIFIER ACC REPLACE±AGenuine Vornado Accessories Are RecommendedPeak performance is only realized when genuine Vornado Advanced Carbon Filte

Page 8 - About the Glow

16 English3. Remove the Permanent Pre-Filter by pulling on the center tabs (C). You may need to flex the Permanent Pre-Filter slightly to release the

Page 9 - Refill Program

17English5. To remove the Advanced Carbon Filter, after the Permanent Pre-Filter and HEPA Filter have been removed, take hold of tab along the perimet

Page 10 - Understanding CADR

18 English7. Replace the Permanent Pre-Filter by securing the bottom 2 tabs into bottom slots (D). Slightly flex the Permanent Pre-Filter to se-cure th

Page 11 - Control Panel

19EnglishFilter Replacement9. To reset the Replacement notification - Press and hold the RE-PLACE CARBON, REPLACE HEPA, REPLACE SCREEN, REPLACE UV BULB

Page 12 - How To Use

2 EnglishDesigned, engineered and supported in Andover, Kansas. Pensado, diseñado y respaldado en Andover, Kansas. Conception, mise au point et soutie

Page 13

20 English±silverscreen™ Tray and UV Bulb ReplacementReplacing Trays1. Unplug unit and remove Front Panel. Refer to FILTER REPLACE-MENT on page 15 for

Page 14 - User Tips

21English4. Replace with only genuine Vornado UV Bulb Tray or sliverscreen™ Trays. Push the Tray into unit until it securely snaps into place.Note: Al

Page 15 - Filter Replacement

22 EnglishCleaning and StorageHow to CleanBecause large volumes of air pass through your Vornado Air Purifier each day, it will need regular cleaning.

Page 16

23EnglishTroubleshootingUnit is not plugged in. Plug power cord into electrical outlet.Household circuit breaker / ground fault interrupter has tripp

Page 17

24 EnglishControl Lock may be enabled. If Control Lock ( ) is illuminated, press the Control Lock ( ) to unlock.The Control Panel is Touch Sen

Page 18

25EnglishVornado Air LLC (“Vornado”) warrants to the original consumer or purchaser this Vornado® Air Purifier (“Product”) is free from defects in mate

Page 19

CL3-0338 RACL7-0338 RA, V01Speak your mind www.vornado.com/reviewsHable con franqueza www.vornado.com/reviewsÉvaluer ce produit en ligne www.vornado.c

Page 20 - Tray and UV Bulb Replacement

3EnglishContentsEspañol p. 26Français p. 49Important Instructions ...4Destroy What HEPA Can’

Page 21

4 EnglishThis appliance has a polarized plug. (One blade is wider than the other.) To reduce the risk of electric shock, this plug is intended to fit i

Page 22 - Cleaning and Storage

5Englishwith the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection

Page 23 - Troubleshooting

6 EnglishDestroys bacteria and viruses smaller than those that cause the flu, common cold and antibiotic-resis-tant infections.*Destroys formaldehyde a

Page 24

7EnglishProduct InformationFront PanelPermanent Pre-FiltersCaptures larger initial particles and odors passing through the unit.HEPA FiltersCaptures 9

Page 25

8 EnglishClean The Air At A Molecular Level silverscreen™ exposes harmful airborne gases and organisms to a very specific spectrum of UV light and a pa

Page 26 - Vornado Air, LLC

9EnglishVornado Whole Room Air Purifiers Feature Precision True HEPA CalibrationWithout properly calibrated air-flow, products with a True HEPA Filter w

Comments to this Manuals

No comments